Member Detail
Product
Leads
Study of a Power Supply (Solid Stat
Study of Second Order Networks
D.C. Speed Control System
Study of Dielectric Constant
Compensation Design
Planck's Constant Experiment
Magnetic Hysteresis Loop Tracer
Thermoluminescence of F-centers
Magnetoresistance Set-up
Study of Temperature Transducers
Digital D.C. Microvoltmeter
Ionisation Potential Setup
Digital Microscope
Electron SpinResonance Spectrometer
IC Regulated Power Supply
Travelling Microscope
Study of P-N Junctions
Four Probe Set-Up (Research Model)
High Voltage Power Supply
Gouy's Method
Study of an Integrated Circuit Regu
Four Probe Experiment
Physics Laboratory Experiments
Hall Effect in Metals
Four Probe Experiment
e/m Experiment
Digital Control System
Quinck's Tube Method
Digital Picoammeter
Digital Gaussmeter
Digital Gaussmeter
Digital Nanoammeter
Basic Operational Amplifier
Study of Modulation and Demodulaion
Study of 741 Applications
Semiconductor Diodes Characteristic
Study of a Solid State Power Supply
Astable & Monostable Multivibrator
Study of Planck's Constant
Magnetic Field Measurement Appt.
Electromagnet & Power Supply
Hall Coefficient on Temperature
Frank Hertz Experiment
PID Controlled Oven
Hall Effect Experiment
Travelling Microscope
Lead Description:
Description
We offer precision Digital Picoammeter very usefull in general laboratory and R&D labs. This is a very versatile multipurpose equipment for the measurement of low dc currents. It has 6 decade ranges with 100% over-ranging from 10-9A to 10-4A. For the ease, readings are directly obtained on a 3½ digit DPM. The instrument uses a well designed precision FET input electrometer operational amplifier AD549, which offers the lowest input bias currents (50fA with ±5V supplies) available in any standard operational amplifier. The excellent characteristics of AD549, ultra low bias current, low offset voltage, low drift and low noise have been fully utilized to obtain best results in the present picoammeter. The first operational amplifier AD549 is used in low level current to voltage configuration and the output has been directly read on a 3½ digit panel meter. The instrument is capable of accepting either polarity of the input current. Well regulated power supplies are incorporated to use the instrument upto 10% changes in a.c. main’s voltage. Features >>Measures current down to 1pA >>All solid state and IC design >>Very low offset current Applications >>Current from Photomultiplier tubes, Photometers etc. >>Leakage currents in solid state devices. >>FET gate and tube grid-voltage without loading errors >>Current through very high resistance’s in conjunction with a power supply >>Potentials across semiconductors, piezoelectric system & pH/plon sensitive electrodes >>Electrical conductivity of air >>Very low current oxygen sensors Specifications: Multiplier: X1, X10, X102, X103, X104, X105 Accuracy: 0.2% for all ranges Resolution: 1pA, 10pA, 100pA, 1nA, 10nA, 100nA Input Resistance: 2.5KΩ, 0.25KΩ, 25Ω, 2.5Ω, 0.25Ω, 0.025Ω Display: 3½ digit 7 segment LED (12.5mm height) with auto polarity Input: Through amphenol connector Power Supply: 220V ±10%, 50Hz Weight: 2.5Kg Dimensions: 240mm X 275mm X 120mm
We offer precision Digital Picoammeter very usefull in general laboratory and R&D labs. This is a very versatile multipurpose equipment for the measurement of low dc currents. It has 6 decade ranges with 100% over-ranging from 10-9A to 10-4A. For the ease, readings are directly obtained on a 3½ digit DPM. The instrument uses a well designed precision FET input electrometer operational amplifier AD549, which offers the lowest input bias currents (50fA with ±5V supplies) available in any standard operational amplifier. The excellent characteristics of AD549, ultra low bias current, low offset voltage, low drift and low noise have been fully utilized to obtain best results in the present picoammeter. The first operational amplifier AD549 is used in low level current to voltage configuration and the output has been directly read on a 3½ digit panel meter. The instrument is capable of accepting either polarity of the input current. Well regulated power supplies are incorporated to use the instrument upto 10% changes in a.c. main’s voltage. Features >>Measures current down to 1pA >>All solid state and IC design >>Very low offset current Applications >>Current from Photomultiplier tubes, Photometers etc. >>Leakage currents in solid state devices. >>FET gate and tube grid-voltage without loading errors >>Current through very high resistance’s in conjunction with a power supply >>Potentials across semiconductors, piezoelectric system & pH/plon sensitive electrodes >>Electrical conductivity of air >>Very low current oxygen sensors Specifications: Multiplier: X1, X10, X102, X103, X104, X105 Accuracy: 0.2% for all ranges Resolution: 1pA, 10pA, 100pA, 1nA, 10nA, 100nA Input Resistance: 2.5KΩ, 0.25KΩ, 25Ω, 2.5Ω, 0.25Ω, 0.025Ω Display: 3½ digit 7 segment LED (12.5mm height) with auto polarity Input: Through amphenol connector Power Supply: 220V ±10%, 50Hz Weight: 2.5Kg Dimensions: 240mm X 275mm X 120mm
Lead Name :
Digital Picoammeter
Model/Article No :
DPM_sesinstrumentspvtltd
Category :
Scientific Equipments and Scientific Instruments
Price :
INR
0.00
Related Searches :
digital picoammeter ,
precision measuring instrument ,
laboratory instrument ,
physics instrument ,
digital ammeter ,
laboratory scientific instrument ,
technical teaching equipment ,
technical training instrument ,
,
Packing :
Per Peice
Manufacturer :
SES Instruments Pvt. Ltd.
SES Instruments Pvt. Ltd.
Contact Details
Address
452 Adarsh Nagar
City :
ROORKEE
Country :
India
Postal Code :
247667
Phone
911332272852
Mobile
919837062750